Reference Design for Interfacing Current Output Hall Sensors and CTs with Differential ADC/MCU (TIDA-00368)

The TIDA-00368 reference design provides a reference solution for interfacing current output Hall sensors and current transformers to differential ADC (standalone and integrated into MCU). The differential signal conditioning circuit is designed to measure motor current with an accuracy of ±0.5% across operating temperature range from -25°C to +75°C. The output common-mode voltage of the differential amplifier can be selected to either 1.25V or 2.5V.

Возможности

On board current-output Hall sensor to measure nominal current up to 25A RMS Current measurement accuracy of 0.5% Common reference solution for interfacing both CT and current output hall sensor with Pseudo-differential ADC/MCU Selectable output common-mode voltage for the differential amplifier Provision to evaluate with Delfino F2837x Control Card Provision to evaluate with external ADC (ADS8354) for interfacing with Motor Controller

Файлы

Схемы и диаграммы

Быстро получите общее представление о схемотехнике решения

Печатные платы и ПО

Ускорьте разработку по готовому дизайну

Спецификация (BOM)

Загрузите полный список требуемых компонентов.

Reference Design for Interfacing Current Output Hall Sensors and CTs with Differential ADC/MCU TIDA-00368

Возможность заказа

Покупка BOM TIDA-00368

Вы будете перенаправлены на страницу выбора предложений по позициям, входящим в состав типового решения TIDA-00368

Покупка печатной платы для TIDA-00368

Цена: 3999 ₽
от 3 шт. 2364 ₽
от 5 шт. 2056 ₽
Срок поставки 3 недели